Input Wiring Specifications; 2.05.01 1 Phase Input Cable Wiring Requirements - ESAB THERMAL DINAMICS CUTMASTER 60i Operating Manual

Plasma cutting system
Hide thumbs Also See for THERMAL DINAMICS CUTMASTER 60i:
Table of Contents

Advertisement

2.05

Input Wiring Specifications

WARNING
Each CutMaster 60i system is a dedicated 1 Phase OR 3 Phase system and cannot be reconfigured to the other.
Personal injury could occur if changing the phase is attempted.

2.05.01 1 Phase Input Cable Wiring Requirements

1 Phase CutMaster 60i Power Supply Input Cable Wiring Requirements
Input voltage
Volts
208
230
380
1 Phase
400
415
480
2.05.02 3 Phase Input Cable Wiring Requirements
3 Phase CutMaster 60i Power Supply Input Cable Wiring Requirements
Input voltage
Volts
208
230
380
3 Phase
400
415
480
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
0-5561
Freq Power Input
Hz
kVA
50/60
8.9
50/60
8.9
50/60
8.9
50/60
8.9
50/60
8.9
50/60
8.9
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
Single Phase
Freq Power Input
Hz
kVA
50/60
9.1
50/60
9.1
50/60
8.9
50/60
8.9
50/60
9.1
50/60
9.2
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
INTRODUCTION
Suggested Sizes
Fuse
I max
I
eff
(amps)
1
43
30.5
50
38.9
27.6
50
23.5
16.7
30
22.4
15.9
30
21.6
15.3
30
18.6
13.2
30
Suggested Sizes
Fuse
I max
I
eff
(amps)
1
26
18.5
40
23.3
16.5
30
13.8
9.8
20
13.2
9.4
20
12.8
9.1
20
11.3
8.0
15
CUTMASTER 60i
Flexible Cord (Min.
AWG)
8 AWG (10mm 2 )
10 AWG (10mm 2 )
12 AWG (2.5mm 2 )
14 AWG (2.5mm 2 )
14 AWG (2.5mm 2 )
14 AWG (2.5mm 2 )
Flexible Cord (Min.
AWG)
12 AWG (2.5mm 2 )
12 AWG (2.5mm 2 )
14 AWG (2.5mm 2 )
14 AWG (2.5mm 2 )
16 AWG (1.5mm 2 )
16 AWG (1.5mm 2 )
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

A-14029

Table of Contents