Input Wiring Specifications - ESAB A-14032 Operating Manual

Plasma cutting system
Table of Contents

Advertisement

CUTMASTER 60i
2.05

Input Wiring Specifications

WARNING
Each CutMaster 60i system is a dedicated 1 Phase OR 3 Phase system and cannot be reconfigured to the other.
Personal injury could occur if changing the phase is attempted.
3 Phase
3 Phase CutMaster 60i Power Supply Input Cable Wiring Requirements
Input voltage
Volts
208
230
380
3 Phase
400
415
480
Line Voltages with Suggested Circuit Protection and Wire Sizes
NOTE!
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
Cable size is de-rated based on the Duty Cycle of the equipment.
18
Freq Power Input
Hz
kVA
50/60
9.1
50/60
9.1
50/60
8.9
50/60
8.9
50/60
9.1
50/60
9.2
Based on National Electric Code and Canadian Electric Code
INTRODUCTION
Fuse
I max
I
eff
(amps)
1
26
18.5
23.3
16.5
13.8
9.8
13.2
9.4
12.8
9.1
11.3
8.0
Three Phase
Suggested Sizes
Flexible Cord (Min.
AWG)
12 AWG (2.5mm 2 )
40
12 AWG (2.5mm 2 )
30
14 AWG (2.5mm 2 )
20
14 AWG (2.5mm 2 )
20
16 AWG (1.5mm 2 )
20
16 AWG (1.5mm 2 )
15
0-5562