1. Select Factory Defaults and confirm the operation when prompted.
2. Answer the configuration prompts. These are similar to those displayed when you
first powered-up the panel (see page 27).
3. To delete all users, remove and reconnect all power to the panel immediately after
using Factory Defaults (before you exit the Installer menu). You will need to repeat
step 2 when you re-apply power.
4. Exit the Installer menu. The system scans the bus and finds the devices (see page 40).

8.3 Installer Options

8.3.1 Installer Name

The installer name is recorded against installer events in the log. When viewing the log, you can
toggle between showing the user (installer) number and name using left/right keys.

8.3.2 Installer Code

This code allows you to enter the Installer menu (which also carried out an Installer reset).
The Installer code does not allow you to set or unset the system.

8.3.3 Installer Timeout

The installer is automatically logged out of the Installer menu if there is no activity after the
specified period.

8.3.4 Service Date

This option allows you to specify the date when the next maintenance service of the system is
due. If Service Banner is enabled, the message "SERVICE REQUIRED" is displayed at keypads up to
four hours after the start of the Service Date.

8.3.5 Service Banner

Enabling this option allows the "SERVICE REQUIRED" message to be displayed at keypads on the
date specified by Service Date.

8.4 Confirmation

The options in the Confirmation menu depend on the Confirmation Mode you select.

8.4.1 Confirmation Mode

The confirmation mode setting is only available when the country preferences are set
to "UK" (see page 27). If another country is selected, the basic confirmation mode is
always used.
The Confirmation Mode setting determines what events the alarm panel requires to generate a
"confirmed alarm":
Basic - A confirmed alarm is generated when a second detector group alarm is
activated while the system is in an alarm state.

8.4.2 Entry Alarm Delay

Use this option to determine what the system will do if a user strays from an Entry Route zone
during entry. (This option is available to provide compliance with EN 50131-1.)
Disabled
Makes the system give an alarm immediately a user triggers a zone other than the entry
route zone during entry.