Abus AZAA10000 Installation Manual page 28

Terxon sx alarm panel
Hide thumbs Also See for AZAA10000:
Table of Contents

Advertisement

8.
Select the wiring type to use for wired zones:
WIRED ZONE TYPE
*2-wire FSL 2k2/4k7
You can change the wiring type by pressing  one or more times. Press ✓ to
continue.
Further information about zone wiring types is given on page 13.
Note: You can change this setting later using Installer menu – System
Options.
9.
If you selected the UK as the country version, specify the alarm confirmation mode:
CONFIRMATION MODE
*BS8243
You can change the confirmation code by pressing  one or more times. Press ✓ to
continue.
Please refer to page 54 if you need information about confirmation modes. You can
change this setting later using Installer menu – System Options – Confirmation –
Confirmation Mode.
10.
User codes (e.g. to set or unset the system) can be four or six digits long. Select the
required length:
USER CODE FORMAT
4 Digit User Codes
Press  if you want to select six-digit user codes. Press ✓ to continue.
Note: you can change this setting later using Installer menu – System
Options – Restore Defaults – Staged Defaults – Users.
11.
Specify an installer code:
NEW INSTALLER CODE
(
Use the numeric keys to specify the code. When prompted, confirm the code with ✓.
Do not forget this code!
12.
Specify a code for the default master user:
NEW USER 1 CODE
(
Use the numeric keys to specify the code. When prompted, confirm the code with ✓.
Do not forget this code!
13.
You will see one of the following:
If the lid of the panel is closed, you will see the standby screen. For example:
TERXON SX
00:00
If the lid of the panel is open, you will see:
INSTALLER EXIT FLTS
Panel lid open
)
)
01/01/2020
28