• Leave On Time, Off Time and Days without values if you want the output to act as a
simple on/off switch under the control of the user.
Line Fault (44)
Active when the panel detects a communications fault. Deactivates when the
communications fault clears
Courtesy Light (45)
Active when the entry or exit timer is running. The panel activates this output when the
entry or exit time starts, and deactivates the output 10 seconds after the entry or exit time
stops.
Installer on Site (46)
The panel activates the output when an installer enters the Installer menu, and deactivates
the output once the installer has exited the Installer menu.
Duress Code (47)
Active when a user keys in a Duress code and deactivates the output when a user or
engineer resets the system.
HUA Confirmed Alarm (48)
Although this output type is always available in the menu, it operates only when BS8243 is
enabled.
Active when there is an HUA Confirmed Alarm (see page 54).
Lockset Unlocked (49)
The panel activates the output when the Lock Set zone is activated and deactivates the
output when a Lock Set zone is deactivated.
Burg Confirm timer (50)
Active when a Burg confirmation timer is running. Inactive when the timer stops.
Although this output type is always available in the menu, it operates only when BS8243 or
DD243 is enabled.
HUA Confirm Timer (51)
Active when an HUA confirmation timer is running. Inactive when the timer stops.
Although this output type is always available in the menu, it operates only when BS8243 is
enabled.
Rearmed (52)
The panel activates the output if the system re-arms at least once after the user armed it.
If Confirmation Mode (page 54) is set to BS8243 or DD243, the panel activates the output
as it rearms the system after the confirmation timer expires.
If Confirmation Mode is set to Basic, the panel activates the output as it rearms the system
when the bell/siren time expires.
The panel deactivates the output when a user or installer resets the system.
Burg Confirmed Alarm (53)
Active when there is a Burg Confirmed Alarm (see page 54).
The panel deactivates the output when a user or engineer resets the system.
Entry Only (71)
Note: If a user activates the output while it is deactivated, the
output stays activated until the panel reaches the next off time. If a
user de-activates the output while it is activated, the output
deactivates until the panel reaches the next on time.
46