Keypad Text; Restore Defaults; Staged Defaults; Factory Defaults - Abus AZAA10000 Installation Manual

Terxon sx alarm panel
Hide thumbs Also See for AZAA10000:
Table of Contents

Advertisement

Remote Reset (RedCare Reset)
If you select NO for System Tampers, then when a tamper occurs, the panel enables the
Remote Reset input pin on the plug-by connector. After an alarm, the user may silence the
sounders, but to reset the system, the user must first contact the ARC. The ARC (after
verifying the user's identity) can cause the Remote Reset input to go to +12V by way of the
plug-by communicator. On receiving the signal, the panel allows the user to reset the
system.
If the ARC causes Remote Reset to go to +12V and it reverts back to 0V before the user
resets the system, the panel remembers that the signal has been sent and still allows the
user to reset the system using their normal access code.
Code Tampers
Yes – The user can reset the system after an alarm caused by a code lockout (see page 30).
No – The installer must reset the system after an alarm caused by a code lockout.

8.1.3 Keypad Text

This allows you to specify the text that appears on the first line of the display in the standby
screen (such as your company name). See page 31 for editing text.

8.2 Restore Defaults

8.2.1 Staged Defaults

This menu option allows you to default parts of the panel's configuration without affecting the
whole system. You can choose to default the following:
Users
Defaults (removes) all user access codes, including for the master user. You are prompted
to enter a new code for the master user.
You can also choose whether to use 4-digit or 6-digit codes.
If you change from 4-digit to 6-digit codes, two additional zeros are added to the end of the
existing installer code. If you change from 6-digit to 4-digit codes, the final two digits are
removed from the end of the existing installer code.
User 001
Defaults (removes) the master user settings, including the user access code, proximity
reader tag, etc. You are prompted to enter a new code for the master user.
Zones
Defaults all information relating to zones (e.g. zone types and attributes).
Outputs
Defaults all output configuration.
Setting Information
Defaults all setting options.
System Options
Defaults all options in the System Options menu.
Communications
Defaults all configuration for communications.

8.2.2 Factory Defaults

This removes all configuration from a panel, including all names and stored texts, but not the log.
To use the option:
53