6.
Wired zone connections
You can connect up to 10 wired detectors (0 to 9) to the panel using the Fully-
Supervised Loop (FSL), 4-wire Closed Circuit (CC) or 2-wire CC wiring method (Figure
5, page 19). You must use the same method for all detectors. If 4-wire CC is used, the
number of zones is halved and are numbered 1-5.
For any method, the total wiring and switch resistance must be less than 100 Ohms
(EOL resistor shorted in the case of FSL).
By default, the system assumes normally-closed contacts. Detectors with normally-
open contacts must be programmed with the "Inverted" attribute set.
Please refer to 2.3 Detector (zone) wiring types on page 17 in this guide for wiring
details if you want to use two detectors per zone.
Zone 0
Zone 1
FSL Wiring (default)
Zone 0
EOL
EOL
Zone 1
FSL Wiring, with 8k2 resistors
Figure 7 – Wiring Types
7.
Kick-start link
Ordinarily, the panel starts only after the mains supply is switched on, even if a
battery is connected. If you want to operate the panel temporarily using only the
battery, start the panel by briefly shorting this link.
8.
Reset codes link
You can use this link to reset the installer and all user codes (e.g. in the event that
codes have been forgotten). This link can be enabled or disabled by a setting in the
Installer menu. Please refer to 4.5.3 Resetting Access Codes on page 32 for further
details.
2-Wire CC Wiring
Alarm
Tamper
Z0
Z1
Tamper
Alarm
8k2
8k2
Alarm
Tamper
Z0
Z1
Tamper
Alarm
8k2
8k2
4-Wire CC Wiring
Alarm Zone 1
Tamper Zone 1
Supported resistor values (+- 5%)
EOL
Alarm
2k2
4k7 (default)
1k0
1k0
2k2
2k2
4k7
4k7
23