Appendix A: Log Messages
Introduction
This Appendix gives short explanations of the messages that may appear in the panel's log.
Please note that many of the messages refer to specific devices by the bus and device number.
Therefore, it is not possible to show in this list the exact log message that you may be seeing on
any given installation.
The list itself is sorted alphabetically by the text of the message. In the column "Event Log Text"
you will see "==" or sometimes "#". These characters stand in for the zone, user or device number
that the panel has recorded for the event being logged. In the "Description" column this is shown
as "n".
Log messages
Event Log Text
(Scantronic)
"== Ex Keys Rstr"
"24hr Z=== Alarm"
"24hr Z=== Restore"
"A/C Fail"
"A/C Restore"
"Alarm Abort U--"
"Alarm Conf ==ER"
"Alarm Conf Bell #"
"Alarm Conf. =="
"Alarm Confirm Z=="
"Alarm Confirm"
"Alm Conf Bus# Tamp"
"Alm Conf Panel Lid"
"ATE L.F. All"
"ATE L.F. Restore"
"ATE L.F. Single"
"Auxiliary 12V Fail"
"Auxiliary 12V Rstr"
Description
Excess keys (code attempts) tamper
restore
24 hour alarm on zone n
24 hour alarm on zone n restored
AC mains failed and was
communicated
AC mains was restored
Alarm aborted by user n
Alarm has been confirmed by a
missing external prox reader on
keypad n
Confirmed alarm with tamper on Bell
n
Confirmed alarm with tamper on
keypad n
Confirmed alarm on zone
Confirmed alarm
An alarm was confirmed by a bus
tamper
Confirmed alarm with tamper on
panel lid
All lines to alarm transmission
equipment failed
Line to alarm transmission equipment
restored
Alarm transmission equipment has a
single line fault
Panel 12V Aux DC not working
Panel 12V Aux DC restored
"Bad checksum"
"Batt = Fault Rst"
"Batt = Low/Missing"
"Bell # 12V Fail"
"Bell # 12V Restore"
"Bell # Tamper Rstr"
"Bell # Tamper"
"Burg Z== Alarm"
"Burg Z== Restore"
"Burg Z=== Alarm"
"Burg Z=== Restore"
"Bus # 12V Fail"
"Bus # 12V Restore"
"Bus # Tamper Rstr"
"Bus # Tamper"
"Codes Defaulted"
"Configuration Fail"
"Defaults Loaded"
"Disabled =="
"Dup. == Restore"
"Duplicate =="
"Enabled =="
"Entry Started Z=="
There is an error on loading the panel
with its software
Panel battery restored
Panel battery missing or low
12V DC supply to bell n failed
12V DC supply to bell n restored
External wired siren n tamper
restored
External wired siren n tamper
Burglar alarm on zone n
Burglar alarm on zone n restored
Burglar on First linked zone n in Beam
Group
Burglar on First linkedzone n in Beam
Group restored
12V DC supply to Bus n failed
12V DC supply to Bus n restored
Bus n has been restored
Bus n has been tampered (for example
wires cut or disconnected)
All access codes were returned to
factory defaults
The current configuration is not
compatible with the software revision
level of the panel
The panel was returned to factory
defaults
Keypad n disabled
Duplicate keypad restored
Duplicate keypad n detected
Keypad n enabled
Entry started by zone n