Inverted
On FSL zones, the attribute makes the panel treat resistances in the 6k9 band as "tamper",
and resistances below the 2k2 band as "alarm". In 4-wire CC zones the attribute makes the
panel treat open alarm contacts as "no alarm" and closed alarm contacts as "alarm".
(Tamper contacts are not affected by the Invert attribute.)
You can apply this attribute to any zone type except Tamper Return and Not Used.
Linked Zone
If a zone activates that has this attribute, a second zone with this attribute must also
activate within the Linked Zone Time (see page 58) for an alarm to trigger.
This attribute is normally used only for an area protected by an array of infra-red beams,
with each beam connected to a separate zone.
Extended Entry Time
This attribute is only for Final Exit zone types. If enabled and the zone is triggered to start
the entry procedure, the system uses the Extended Entry Time setting (page 49). If disabled,
the system uses the standard Entry Time setting (page 49).
This attribute allows for cases where you need to allow an increased length of time for the
entry procedure for certain zones. For example, you may want to allow 40 seconds for a
front door, and 90 seconds for a garage entrance.
Double Doors
This attribute is available only if the zone is configured to use the 2k2/4k7 FSL wiring
method (see page 57). Setting this attribute allows the zone to monitor two door contacts
in series, providing each detector has a 4k7 shunt resistor and there is a 2k2 end-of-line
resistor. Please refer to page 18 for wiring details.
To enhance system security, it is not recommended to use this attribute if only one
detector is connected to the zone.
Force Set
This attribute is for zones of type Key Switch Momentary and Key Switch Latched only.
You may wish to allow the key switch to set the alarm system even if one or more zones are
active or have faulty detectors. This is known as a "force set". The detectors that are active
or are faulty must have the Force Set Omit attribute set to Yes. When a force set occurs, the
system omits the active or faulty zones and sets the remaining zones normally.
Off – The key switch cannot force set the system, even if you have applied the Force Set
Omit attribute to any zones.
On – The key switch can force set the system.

5.2 Address Bus Device

You can use this option to:
Add new keypads to the system once they are physically wired to the bus. The panel
assigns a bus address to each keypad you add. (You can perform the same action using
Detectors/Devices – Wired Keypads – Address Bus Device.)
Re-scan the bus for any found or missing keypads.
Note: If you need to replace or remove a keypad, please use Delete Keypad (page 32)
or Replace Keypad (page 33).
39