Silence Alerts
This option controls the length of time that keypads and loudspeakers give the alert tone (a
brief 'beep' every second) when there is an alert.
Note:
Some alerts are associated with a specific part of the system (such as an alert
generated by a detector of type Technical Alarm that is in a part set). Other alerts
are associated with the whole system (such as an alert generated by a low
backup battery). An alert is not sounded if all part sets the alert is associated
with are set.
User Code – The alert tone is sounded until a user keys in an access code to acknowledge
the alert.
30/60/120 minutes – The alert tone is sounded for the selected time. The alert tone stops if
a user enters a valid access code.
No Alert Tones – There is no alert tone.

8.1.2 User Reset

This option determines under what circumstances a user or the installer can reset the system
after an alarm.
Zone Alarms
This appears when System Options – Confirmation – Confirmation Mode is set to Basic
(page 54).
Yes – The user can reset the system after an alarm triggered by a zone's alarm circuit.
No – The installer must reset the system after an alarm triggered by a zone's alarm circuit.
See also "Remote Reset" on page 53.
Note: Users can reset the system if they unset the system during an alarm, but
before the Alarm Abort period has expired (see page 56).
Zone Tampers
Yes – The user can reset the system after an alarm caused by a zone's tamper circuits being
triggered.
No – The installer must reset the system after an alarm caused by a zone's tamper circuits being
triggered. The alarm abort period does not apply.
System Tampers
Yes – The user can reset the system after an alarm caused by a system tamper.
No – The installer must reset the system after a system tamper alarm. The alarm abort
period does not apply.
A system tamper can be caused by, for example:
Operating a lid/back tamper switch on a device.
Applying a voltage higher than approximately 4V to the TR input from an external sounder.
If a tamper occurs when the system is set, the panel classifies this as an unconfirmed or
confirmed alarm. The reset follows the alarm reset option NOT the tamper.
• Keypad navigation keys glow red when there is an alert sounded at the
keypad (or if there would have been an alert sounded if had not been
for the selection of No Alert Tones).