Wired Keypads; Address Bus Device; Edit Keypad; Delete Keypad - Abus AZAA10000 Installation Manual

Terxon sx alarm panel
Hide thumbs Also See for AZAA10000:
Table of Contents

Advertisement

If you are re-scanning the bus through Address Bus Device, the display shows:
Press addr button(s)
on bus devices
If there are new keypads, continue as described in the previous section. Alternatively,
press  if there are no new keypads.
Changes are not saved until you leave Installer menu. If the panel loses power before
leaving Installer menu, the bus re-configure does not take effect.

5.3 Wired Keypads

5.3.1 Address Bus Device

You can use this option to add a wired keypad to the system once it is physically wired to the bus.
This is an alternative to using Detectors/Devices – Address Bus Device. For further information,
please refer to page 39.

5.3.2 Edit Keypad

You can use this option to edit settings for a specific keypad.
Note: If you wish to find out where the device is located, press "*". The displayed
device will sound a continuous tone. Press "#" to stop the tone.
Name
You can give each keypad a name. The panel displays the name when it is reporting faults or other
events, making it easier to locate the affected device.
Key A/B/C/D
These options allow you to program the A, B, C and D (quick-set) keys. You can enable the quick-
set keys to full set the system, or set part sets B, C and D. To choose the setting method, select
Action, Set, and then the required option. Each keypad can have a different arrangement of quick-
set keys.
Each quick-set key can have a name. The keypad displays this name while the system is setting
after the user presses that key.
Note:
The ABCD LEDs at the keypad show the state of the quick-set keys. When the
part set that a quick-set key is allocated to is set, the associated LED glows.
The panel logs the use of quick-set keys

5.3.3 Delete Keypad

Always use Delete Keypad when you wish to remove a wired keypad from the bus. Using this
option defaults the bus device number stored within the device (making the device safe to add to
other systems). Exit the Installer menu to save the change.
Note: Remove all power from the system (battery and mains) before disconnecting any
keypad from the bus.
Holding down D and  at a keypad while its tamper switch is open clears the address from the
keypad. Normally, you should clear the address only by using Delete Keypad. If you have used D
and  at a keypad that is known to the system and still connected to the bus, you can either
power the panel down and up again for it to recognise the keypad (you will be prompted to press
the A and ✓ keys), or go to another keypad and use Delete Keypad to delete the keypad.
41