HUAs have an alarm sound that is distinct from other alarm types.
Fire Alarm - FA (02)
Smoke or heat detectors connected to Fire Alarm zones cause keypads, loudspeakers and
the external siren to give a pulsing fire signal (subject to the Alarm Response; see page 49).
Fire alarms operate whether the system is set or unset and will always trigger
communications.
Note that a tamper from a hardwired smoke alarm on a Fire Alarm zone when the system is
unset will cause an internal alarm (keypad sounders and loudspeakers only).
Normal Alarm - NA (03)
When triggered, a zone of type Normal Alarm will start an alarm provided the system (or
part set) is set.
24 Hour Alarm - 24 (04)
Activating this zone while the system (or part set) is unset causes an internal alarm
(keypads and loudspeakers). Activating this zone while the system (or part set) is set causes
an alarm from internal sounders and the external siren (subject to the Alarm Response; see
page 49).
Final Exit – FE (05)
Zones of this type must be the last detector to be activated on exit, or the first to be
activated on entry. You can use zones of this type to complete the setting of the system, or
to start the entry procedure. See page 48 to set the exit mode type.
Note: If you give a Final Exit zone any of the Part Set attributes, you can program that
zone to behave like a Normal Alarm zone if the user part sets the system. See page 50.
Entry Route – ER (06)
Use this zone type for detectors sited between the Final Exit door/detector and the location
where the system is set/unset. If the entry/exit timer is running when an Entry Route zone
is triggered, no alarm occurs until the entry/exit timer expires.
Note: If you give an Entry Route zone one of the Part Set attributes, you can program
that zone to behave like a Final Exit zone if the user part sets the system. See page 50.
Technical Alarm –TA (07)
Use this zone type when you want to monitor equipment, for example a freezer, without
raising a full alarm. If a Technical Alarm zone is activated, the panel logs the event,
generates a fault condition, and (if the panel is correctly programmed, see page 59Fehler!
Textmarke nicht definiert.) starts communication.
If the technical alarm occurs while the system is set, the system makes no audible alarm.
When a user unsets the system, the display shows an alert.
If a Technical Alarm zone is activated while the system is unset, the system starts an alert
immediately and gives a brief tone at keypads and loudspeakers every few seconds. When a
user enters a valid access code, the tone stops and the display shows the zone causing the
alarm.
When the user acknowledges the alert by pressing ✓, the panel resets the technical alarm
ready for the next event.
Note that a tamper on a Technical Alarm zone when the system is unset will cause an
internal alarm.
Key Switch Moment. – KSM (08)
Use this zone type to connect a momentary keyswitch to a single zone.