Time (see page 49) expires, the panel sets the system and converts the Final Exit zone to a
zone of type Normal Alarm.
Unsetting: When a user de-activates the Lock Set zone, the panel converts any zone
originally programmed as Final Exit back to Final Exit (so that the entry time starts when the
user opens the entry door) and starts a warning tone (distinct from the entry tone). If the
user activates the Lock Set zone again without starting the Entry Timer, the panel changes
all Final Exit zones back into Normal Alarm zones and stops the warning tone.
Exit Terminate
Setting: The user must start the setting sequence in the normal way, and then complete
setting in one of the following ways once they have left the protected area:
By activating an Exit Terminate zone (see page 35).
When the user starts the setting sequence, the exit tone is sounded and the exit time does
not expire. Once the user completes the setting sequence, the system sets when the Settle
Time (see page 49) expires.
The user can unset using any of the following methods:
By presenting a proximity tag to an external proximity tag reader.
By activating a Final Exit zone (to start an entry timer) and then entering an access
code or presenting a proximity tag to a keypad.

7.1.3 Settle Time

This option is available only if Exit Mode is set to Final Door Set, Lock Set or Exit Terminate. This
option allows you to define a time delay to allow detectors to settle before the system sets.
During this period, the sounders stop and the panel ignores any alarms generated by the
detectors.
Enter two digits to specify a time in seconds, from 01 to 30.

7.1.4 Exit Time

This option is available only if Exit Mode is set to Timed Set or Silent Set. The exit time can take
any value between 10s and 120s.

7.1.5 Entry Time

The entry time can take any value between 10s and 120s. The entry time you select in this option
applies to full set and all part sets.

7.1.6 Extended Entry Time

This defines the entry time for Final Exit zone types that have the Extended Entry Time attribute
enabled (see page 39).

7.1.7 Alarm Response

Note: This is available only for a part set. The response for a full set is always
Siren + Comms.
Internal: Keypads and loudspeakers.
Siren: External sirens, keypads and loudspeakers.