User Preferences - Eaton NetDirector B064-016-04-IPH Manual

Hide thumbs Also See for NetDirector B064-016-04-IPH:
Table of Contents

Advertisement

OSD Operation

User Preferences

The User Preferences page allows users to set up their own
individual working environments. The B064-Series KVM
Switch stores a separate record for each user profile, and sets
up the working environment according to the Username that
was used to access the KVM switch. Note: The User Preferences
page is different on the Web Browser version than the AP Client
version. The AP Client version does not include the password,
Viewer or Welcome Screen option.
The page settings are explained in the following table:
Setting
Description
Language
Selects the language that the interface displays in. Options are English (default), Spanish, French,
German, Russian, Italian, Japanese, Korean, traditional Chinese and simplified Chinese.
OSD Hotkey
Selects which hotkey controls the OSD function. You can choose from the following options; [Scroll Lock]
[Scroll Lock], [Ctrl] [Ctrl], [Alt] [Alt], [Shift] [Shift] and [Print Screen] [Print Screen]. The default is [Scroll
Lock] [Scroll Lock].
ID Display
Selects how the Port ID is displayed: the Port Number alone (PORT NUMBER); the Port Name alone
(PORT NAME); or the Port Number plus the Port Name (PORT NUMBER + PORT NAME). The default is
PORT NUMBER + PORT NAME.
ID Duration
Determines how long a Port ID displays on the monitor after a port change has taken place. You can
choose an amount from 1—255 seconds. The default is 3 seconds. A setting of 0 (zero) means the Port
ID is always on.
Scan Duration
Determines how long the focus dwells on each port as it cycles through the selected ports in Auto Scan
Mode. Key in a value from 1—255 seconds. The default is 5 seconds; a setting of 0 disables the Scan
function.
Screen Blanker
If there is no input from the console for the amount of time set with this function, the screen is blanked.
Key in a value from 1—30 minutes. A setting of 0 disables this function. The default is 0 (disabled). When
the screen is blanked, simply moving the mouse over the screen will bring it back up.
Note: This setting affects the monitor of the local console only.
Logout Timeout
If there is no user input for the amount of time set with this function, the user is automatically logged out.
A login is needed before the B064-Series KVM Switch can be accessed again. The default is 30 minutes.
Toolbar
The Toolbar option allows you to enable/disable the OSD Toolbar. (See The OSD Toolbar section under
Remote Session Operation for details.) As all of the features of the OSD Toolbar are available in the
Control Panel, you may want to disable it. The default setting is enabled.
Viewer
In the browser version of this page, a viewer section is available. You can choose which viewer method is
preferred when connecting to a port by clicking the up or down arrow to shift around the viewer method
position. Usable viewers are automatically determined by the status of the system at the time of the login
and by browser type. When you try to connect to a port (double-click the port or select a port and click
Connect), the system will use the viewer according to the viewer list.
· The top-most method is the most preferred method (web client by default).
· If the preferred method is supported when connecting to a port, the system will try connecting using
· If the method is not supported, the system will try connecting using the next method. Try this method
For B064-008-01-IPG and B064-016-01-IPG models, both user preference and password settings
are located at upper right-hand corner of User Icon . Please see details at IPG's User settings
section in OSD Operation chapter .
the preferred method.
last.