Statement of Compliance Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications.
Page 4
PRODUCT PACKAGING (2155.53 / 2155.55) One of the following: Soft Carrying Pouch Megohmmeter Model 6526 - Cat. #2155.53 (7.75 x 9.25 x 2.75) in Megohmmeter Model 6534 - Cat. #2155.55 Cat. #2119.02 (2) Color-coded Grip Probes Cat. #2152.26 (2) Color-coded (Red/Black) Test Leads with...
Page 5
Example: hardwired equipment in fixed installation and circuit breakers. CAT II corresponds to measurements performed on circuits directly connected to the electrical distribution system. Example: measurements on household appliances and portable tools. Megohmmeter Models 6526 & 6534 - Quick Start Guide...
Page 6
Replace all batteries at once. Use alkaline batteries. Use personal protection equipment where appropriate. ■ All troubleshooting and metrological checks must be done by competent, ■ accredited personnel. Megohmmeter Models 6526 & 6534 - Quick Start Guide...
Page 7
Function keys TEST button to start insulation measurements Rotary switch to choose the function or to turn the instrument OFF. The table below lists the functions available for each model instrument. Megohmmeter Models 6526 & 6534 - Quick Start Guide...
Choose the continuity test current. Program the alarm thresholds. Sets the present measurement as a “zero reference” to which ∆ future measurements are compared. Records measurements. Erase recorded measurements. Enable Bluetooth wireless communication. Megohmmeter Models 6526 & 6534 - Quick Start Guide...
3. Open the Bluetooth Devices dialog on your computer to pair the instrument with your computer. Different operating systems have different steps for opening this dialog, so consult your computer’s documentation for instructions. Megohmmeter Models 6526 & 6534 - Quick Start Guide...
5. Once you select the recording number, you can see all information associated with the measurement. Press the MEM key for >2 seconds, then use the key to scroll the information. 6. When finished viewing recordings, press MEM for >2 seconds. Megohmmeter Models 6526 & 6534 - Quick Start Guide...
E-mail: repair@aemc.com (Or contact your authorized distributor.) Contact us for the costs for repair, standard calibration, and calibration traceable to N.I.S.T. NOTE: You must obtain a CSA# before returning any instrument Megohmmeter Models 6526 & 6534 - Quick Start Guide...
Phone: (800) 945-2362 (Ext. 360) / (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 E-mail: repair@aemc.com Caution: To protect yourself against in-transit loss, we recommend that you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument Megohmmeter Models 6526 & 6534 - Quick Start Guide...