3.4. Setting when the power is turned ON for the first time
Description
●
Sets parameters for piping and measurement fluids.
You can set and change them later in 3.8Measurement settings.
Be sure to set the following parameters before mounting the flowmeter to a pipe.
●
Set the accurate pipe outer diameter and wall thickness dimensions. Otherwise, performance can be impaired.
●
If the exact parameters are not set, there will be large measurement errors.
●
Wave receipt errors may also occur.
Item
1. Pipe outer diameter :
2. Pipe material
3. Pipe thickness
4. Measurement fluids :
For specific key operations, refer to the typical operation indicated below.
Operation (example)
Display and keystrokes
1
Measurement display
○ Key
2
○ Key
3
○ Key
4
○ Key
5
○ key, ○ key
6
7
○ Key
8
Measurement display
5.00 to 99.99 [mm] (Factory default: FSZ08: 13.80, FSZ15: 21.70, FSZ25: 34.00 [mm])
:
Carbon Steel, stainless steel (factory default), copper, PVC, PFA, PTFE
:
0.10 to 9.99 [mm] (factory default: FSZ 08: 2.00, FSZ 15: 2.50, FSZ 25: 3.00 [mm])
Water (factory default), seawater, fluid sound velocity
Fluid sound velocity: (Sound velocity: 1000 to 2000 [m/s])
Press the ○ key to go to Display 2.
Pipe outer diameter: 5.00 to 99.99 [mm]
Press the △▽ keys to set the values.
Press the ○ key to go to Display 3.
Pipe material: Carbon steel, stainless steel, copper, PVC,
Press the △▽ keys to set the items.
Press the ○ key to go to Display 4.
Pipe thickness: 0.10 to 9.99 [mm]
Press the △▽ keys to set the values.
Press the ○ key to go to Display 5.
Measurement fluids: Water,
Press the △▽ keys to set the items.
Select water or seawater and press the ○ key to go to Display 7.
Select the fluid sound velocity and press the ○ key to go to Display 6.
Fluid speed velocity: 1000 to 2000 [m/s]
Press the △▽ keys to set the values.
Press the ○ key to go to Display 7.
○ Key
Press the ○ key to return to the measurement display.
Description
,
,
seawater, fluid sound velocity
,
- 18 -
PFA,
,
,
,
,
(initial values)
PTFE