Notes:
1. After resetting, "F9: Output pulse unit" will be set to 1000 [L], and "F14: Fluid selection" will be
set to Air.
2. Qmin is the following value depending on the nominal diameter.
25A
0.6
Setting items include the one related to fluid to be applied, the ones related to measurement and
indication, and the ones related to outputs.

3-1. Measurement and indication setting

Indication of "Forward flow" or "Forward/reverse flow" [F1]
Indication of a main display is set.
When the "Forward flow" is selected, forward accumulated flow volume (total) or accumulated
flow volume (trip) can selectively be indicated on the main display by button operation.
When the "Forward/reverse flow" is selected, forward accumulated flow volume (total) or reverse
accumulated flow volume (total) can selectively be indicated on the main display by button
operation. When the analog output (4-20 mA) is selected for the flow-rate output, the electric
current value of the zero flow-rate output becomes 12 mA.
Flow-rate conversion
Select one among "actual flow-rate (OFF)", "normal conversion flow-rate (Normal)", or "standard
conversion flow-rate (Standard)". If you select "normal conversion flow-rate (Normal)" or
"standard conversion flow-rate (Standard)", both indication and output of accumulated flow rate
and instantaneous flow rate are converted into the values under normal conditions or standard
conditions.
32A
40A
50A
1.1
1.3
2.5
Setting related to measurement and indication 
Forward flow or 
Forward/reverse flow
Flowrate conversion 
or Actual flow rate
65A
80A
100A
4.0
5.0
10.0
 
F1 
 
Indication and output
 
 
F11
Flow‐rate conversion
13
3
[m
/h]
150A
200A
24.0
40.0