Wireless Control Unit
7.10. Mounting
7.10.1 Direct Mounting
The mounting method for the transmitter and receiver are the same.
❶
In the mounting location, drill holes for mounting
and wiring the product.
❷
Rotate the WIO body unit counterclockwise
and detach from the direct mount bracket.
• Detach the bracket in the same way as the head
cover described in "7.13. How to Attach and Detach
Additional Units" ( ☞ page 73).
❸
Use the hexagon nut with flange to secure the
direct mount bracket in the mounting position.
Recommended Torque
(approximate)
❹
Pass the cable through the wire distribution hole.
❺
Remove the two screws from the terminal block
connector and perform the wiring.
• Refer to "7.11.1. Detaching the Terminal Block
Connector" ( ☞ page 46)
• Refer to "7.11.3. Wiring the Terminal Block
Connector" ( ☞ page 47)
❻
Attach the terminal block connector to the
WIO body unit.
• Refer to "7.13. How to Attach and Detach Additional
Units" ( ☞ page 73)
❼
Install the WIO body unit to the direct mount
bracket following the removal procedure in
reverse order.
• Attach the bracket in the same way as the head
cover described in "7.13. How to Attach and Detach
Additional Units" ( ☞ page 73).
❽
If required, apply sealant around the mounting
and wire distribution holes.
The top case
and bottom case
cannot be
removed from
the indicator
Terminal Block
Connector
0.6 N・m
Mounting
Hole
Wire
Distribution
Hole
■
Product Front
Nameplate Location
42
❷
❹
Hexagon Nut
with Flange (M4)
Mounting Dimensions
7. Operation
Head Cover
WIO Body Unit
Indicator
❼
❺❻
Direct Mount Bracket
❶❽
* Maximum board
thickness: 7mm
❸
Mounting Hole
( 5 x 3 places)
Wire
Distribution
Hole ( 20)
Product
Outer
Dimension
( 60)
(Unit: mm)