Item
NT1MOD2ADRS
NT1MOD2NETNO
NT1MOD2STNO
NT1USECO
NT2MOD1
NT2MOD1IO
APPX
378
Appendix 12 Setting Information File Format
Description
Network route
IP address
(module setting
(access target (routed)
system))
Network route
Network No.
(module setting
(access target (routed)
system))
Network route
Station No.
(module setting
(access target (routed)
system))
Network route
Use the co-existence
network route
Co-existence network
Module type
route
(intervening system)
Co-existence network
Head I/O
route
(module setting
(intervening system))
Condition
TYPE is "OWN"
NT1MOD1 is in one of the following
situations
• "CCIEC"
• "CCIEF"
• "NETH"
• "ETHER"
• "CCLINK"
• "SERIAL"
NT1MOD1 is "RDL"
TYPE is "OWN"
NT1MOD1 is in one of the following
situations
• "CCIEC"
• "CCIEF"
• "NETH"
• "ETHER"
NT1MOD1 is in one of the following
situations
• "CCLINK"
• "SERIAL"
NT1MOD2 is "ETHERCPU"
NT1MOD2 is "ETHERMOD"
TYPE is "OWN"
NT1MOD1 is in one of the following
situations
• "CCIEC"
• "CCIEF"
• "NETH"
• "ETHER"
NT1MOD1 is "CCLINK"
NT1MOD1 is "SERIAL"
NT1MOD2 is "ETHERCPU"
NT1MOD2 is "ETHERMOD"
TYPE is "OWN"
Selected
Unselected
TYPE is "OWN"
NT1USECO is "NO"
CC-Link IE Controller Network
Module
MELSECNET/H Module
CC-Link Module
Ethernet Module
Serial Communication module
CC-Link IE Field Network Module
TYPE is "OWN"
NT1USECO is "NO"
NT2MOD1 is in one of the following
situations
• "CCIEC"
• "CCIEF"
• "NETH"
• "ETHER"
NT2MOD1 is in one of the following
situations
• "CCLINK"
• "SERIAL"
Setting value
Remarks
(Blank)
*.*.*.* (IP address)
(Blank)
1 to 239
(Blank)
1 to 239
(Blank)
0 to 120
0 to 63
0 to 31
(Blank)
1 to 120
(Blank)
YES
NO
(Blank)
CCIEC
NETH
CCLINK
ETHER
SERIAL
CCIEF
(Blank)
0 to FE0