Mitsubishi Electric MELSEC iQ-R Series User Manual page 324

High speed data logger module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

■Number of saved files exceeded information (Un\G3012 to 3015)
The information indicating the number of saved files is exceeding the set number of files is stored.
If the operation when the number of saved files exceeds the set number of files is set to "Stop", the system will show inability
to create new files when creating a new file after the number of saved files reached the set number of files.
The bit corresponding to the event logging setting whose number of saved files is exceeding turns ON.
0: Within setting range
1: Setting exceeded
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
Un\G3012
16
15
14
13
Un\G3013
32
31
30
29
48
47
46
45
Un\G3014
Un\G3015
64
63
62
61
To continue logging, delete old files or all files in the directory.
When the number of saved files is less than the set number of files, the corresponding bit turns OFF.
■Event logging information 1 to 64 (Un\G3030 to 3989)
Information about the error which occurred in the event logging function is stored.
Event logging information area is comprised of 64 pieces of event logging information with the same data configuration.
Event logging information 1
Un\G3030 to 3044
Event logging information 2
Un\G3045 to 3059
Un\G3975 to 3989
Event logging information 64
● Error code
An error code is stored in the area corresponding to the event logging setting where the event logging error is occurring.
When errors related to access target CPU occur, the error code of the access target CPU may be stored to other settings
which also use the same access target CPU.
● Number of latest folders
The number of latest folders is stored.
● Number of latest files
The number of latest files is stored.
● High speed sampling failure count
When high speed sampling is selected in the sampling setting and when the data sampling speed cannot catch up with the
timing of the sequence scan or specified time interval, the total number of times for which the data is lacking is stored.
When high speed sampling fails, the following cases occur.
• An event condition establishment may not be detected
• When the data condition is selected in the period setting, the satisfaction of data conditions may not be detected
• Data to be displayed with GX LogViewer is lacking
Take corrective actions by referring to the following:
Page 350 Checking sampling process time
APPX
322
Appendix 3 Buffer Memory
12
11
10
9
8
7
6
5
4
28
27
26
25
24
23
22
21
20
44
43
42
41
40
39
38
37
36
60
59
58
57
56
55
54
53
52
3
2
1
19
18
17
35
34
33
51
50
49
b15
+0
+1
Number of latest folders
+2
+3
Number of latest files
+4
High speed sampling failure count
+5
Processing overload count
+6
+7
Unprocessed buffer size
+8
Unprocessed data count (current)
Unprocessed data count (maximum)
+9
+10
+14
b8
b7
b0
Error code
System area