Network setting

This section explains the settings required for high speed data logger module to establish network connections.
When the network settings are changed, settings are enabled by turning the power OFFON or by resetting the CPU
module.
Window
Click "Common setting" on the edit items tree, then click the [Network setting] button.
Displayed items
Item
*1
IP address setting
Acquire automatically
Specify
DNS server setting
Acquire automatically
Specify
Host name setting
Host name
Network diagnostics
Execute network diagnostics (ping)
setting
Sending interval
Destination
*1 "Acquire automatically" cannot be set in "Common setting"  "Access target CPU setting" when another station is specified to the type
in the access target CPU and "High Speed Data Logger Module Ethernet Port" is set in the "Module type" under "Access source system"
in the [Network route] tab.
Description
Select this to specify the IP address by automatically acquiring it.
Select this to specify the IP address by directly entering it.
IP address
Set the IP address of the high speed data logger module in decimal
notation.
Subnet mask
Set the subnet mask in decimal notation when used.
All devices on the same network must use the common subnet mask.
Default gateway
Set the default gateway in decimal notation.
Only one address can be registered on the high speed data logger
module.
Select this to specify the IP address of the DNS server by automatically
acquiring it.
Select this to specify the IP address of the DNS server by directly entering
it.
Primary server
Set the IP address of the primary DNS server in decimal notation.
Secondary server
Set the IP address of the secondary DNS server in decimal notation.
Set the host name for the high speed data logger module. (Up to 32
characters)
'\' cannot be set.
Used when performing a search on the module or sending e-mail.
Select this to perform network diagnostics and send a ping packet (1
packet) regularly.
Set the Ping packet transmission interval.
Gateway
Select this to send a Ping packet to the gateway.
Following target device
Select this to send a Ping packet to the specified target device. Set the IP
address or host name. (Up to 32 characters)
2 HIGH SPEED DATA LOGGER MODULE CONFIGURATION TOOL
*2
*5
*6
2.4 Common Setting
2
*3
*4
131