Operation settings

Configure the mode setting and default operation settings of the high speed data logger module.
Item
*1
Mode settings
Default
Security
operation
setting
settings
Network setting
For system
For system 1 to 3
*1 For the differences between 'online' and 'online (asynchronous mode)', refer to the following:
Page 239 Online and online (asynchronous mode)
*2 It is available in the following combination.
High speed data logger module: firmware version '06' or later
GX Works3: software version '1.045X' or later
*3 A DNS server is not used.
The network diagnostics (ping) is not executed.
The name specified in the "Network setting" of Configuration Tool is applied to the host name.
The default operation setting is used to change the settings of the high speed data logger module connected
to a personal computer on a 1:1 basis.
3 PARAMETER SETTING
238
3.2 Basic Settings
Description
The operation mode of the high speed data logger module is set.
• Online: It is a normal operation mode.
• Online(Asynchronous Mode): The high speed data logger
module and the CPU module start without synchronization.
• Firmware update: To update the firmware of a high speed data
logger module.
• Module initialization setting: To initialize information retained in a
high speed data logger module.
• Automatic hardware test: H/W such as ROM/RAM/Ethernet of
the high speed data logger module is tested.
• Hardware test for LED check: The LED of the high speed data
logger module is tested.
Account
Set whether or not to change the "Account setting" of the high
setting
speed data logger module forcibly.
• Do not change: Operate by using the setting contents specified in
the "Account setting" of the Configuration Tool.
• Change to default: "Account setting" is disabled and the access
authentication function is not used.
IP filter setting
Set whether or not to change the "IP filter setting" of the high speed
data logger module forcibly.
• Do not change: Operate by using the setting contents specified in
the "IP filter setting" of the Configuration Tool.
• Change to default: "IP filter setting" is disabled and the IP filter
function is not used.
*3
Set whether or not to change the "Network setting" of the high
speed data logger module forcibly.
• Do not change: Operate by using the setting contents specified in
the "Network setting" of the Configuration Tool.
• Change to default: Operate by changing the IP address and
subnet mask as follows:
IP address = 192.168.3.3
Subnet mask = 255.255.255.0
Do not apply the settings as those are used for the system.
Setting range
• Online
*2
• Online(Asynchronous Mode)
• Firmware update
• Module initialization setting
• Automatic hardware test
• Hardware test for LED check
(Default: Online)
• Do not change
• Change to default
(Default: Do not change)
• Do not change
• Change to default
(Default: Do not change)
• Do not change
• Change to default
(Default: Do not change)