■Data line
Column name
Output content
Date column
Outputs data according to the data line output format specified in the Unicode text output setting/CSV
output setting.
(Example) 2016/1/15 10:15:20
Index column
Outputs a numerical value starting from 1 incremented in ascending order.
When the value exceeds the upper limit of 4294967295, it is returned to 0 and increments again in the
range of 0 to 4294967295.
When missing sampling data occurs, the index will be renumbered from 1.
Page 61 Data missing
Data column
Bit
Word [Signed]
Word [Unsigned]/Bit String
[16-bit]
*2*3
16bit BCD
Double Word [Signed]
Double Word [Unsigned]/Bit
String [32-bit]
FLOAT [Single Precision]
FLOAT [Double Precision]
*2*3
32bit BCD
Number of times
Time
Total number of times
Total time
String
Raw
Trigger information
When trigger occurs: (Trigger ON string)
column
When trigger clears: (Trigger OFF string)
Does not output in other situations. (Outputs CR+LF immediately after the tab or comma.)
*1 When a file is opened in Excel, the date column format is displayed in the default setting of Excel.
Set the cell format as necessary.
(Example) To display year, month, date, hour, minute, second, and millisecond information
Specify the user defined display format as follows:
yyyy/mm/dd hh:mm:ss.000
*2 If the device data value cannot be represented with the data type specified in "Data type", and the operation result cannot be
represented with the specified data type, 'NaN' is output to the data line.
*3 For arithmetic processing specified with scaling, all values are calculated as double precision floating point numbers, and the result is
output in the specified output format.
If the result of the linear function transformation with the scaling function exceeds the double precision floating point type upper limit
value, 'Inf' is output. If the value is lower than the lower limit value, '-Inf' is output.
*4 When the numerical values to be output are outside the range of -2147483648.0 to 2147483647.0, they are expressed in a format same
as 'exponential format and 9 digits in the decimal part'.
*1
When data is ON: (String when ON)
When data is OFF: (String when OFF)
Outputs data value according to the output
format specified in the data setting.
Outputs data value according to the output
format specified in the data setting.
*2*3
*2*3
Outputs a string of the specified size.
Outputs the data values of the specified size in hexadecimal notation.
(Example) When outputting raw type data, the size of which is 6 from
D0
Device value: D0=1234, D1=5678, D2=9ABC
Output: 34127856BC9A
Size (bytes)
Unicode
2 to 64
(Depends on
Unicode text
output
setting)
2 to 20
(Depends on
index value)
2 to 32
(Depends on
data setting)
*4
Decimal format
2 to 42
(Depends on
data value
and digits)
Exponential
10 to 42
format
(Depends on
data value
and digits)
Hexadecimal
2 to 8
format
(Depends on
data value)
*4
Decimal format
2 to 52
(Depends on
data value
and digits)
Exponential
10 to 44
format
(Depends on
data value
and digits)
Hexadecimal
2 to 16
format
(Depends on
data value)
*5
2 to 8192
(Depends on
data value
and size)
4 to 32768
(Depends on
size)
0 to 64
(Depends on
Unicode text
output
setting)
Appendix 9 Data Logging File Format
CSV
1 to 32
(Depends on
CSV output
setting)
1 to 10
(Depends on
index value)
1 to 16
(Depends on
data setting)
1 to 21
(Depends on
data value
and digits)
5 to 21
(Depends on
data value
and digits)
1 to 4
(Depends on
data value)
1 to 26
(Depends on
data value
and digits)
5 to 22
(Depends on
A
data value
and digits)
1 to 8
(Depends on
data value)
1 to 8192
(Depends on
data value
and size)
2 to 16384
(Depends on
size)
0 to 32
(Depends on
CSV output
setting)