HPE Nimble Storage HF Series Hardware Manual page 48

Table of Contents

Advertisement

Note: Subnet and VLAN configuration is a separate task.
Procedure
1. After you are logged into the active controller, type:
setup
The Terms and Conditions are displayed.
2. Click Enter to read the Terms and Conditions, then type yes to accept them.
3. Type the following information as requested. Example values are shown here.
Important: Use your own values for each item in the following sample. If you accept an incorrect entry, you must
start the setup process again.
Array name: greyhound
Group name: storehouse
Management IP address: 10.12.128.79
Management netmask: 255.255.0.0
Default gateway IP address: 10.12.255.254
Domain name: admin.storage.com
New password:
4. Specify whether to include IPs in the group certificates: yes or no.
Type yes to include the array's IP address in the certificate. When using this option, you will have to create a new
certificate if the array's IP address changes.
Type no to exclude the array's IP address from the certificate..
5. Specify whether you want to continue the setup in the GUI.
Type yes to open the GUI. Then complete Initial Setup Using the Storage Setup Manager for Windows on page 41.
Ttype no to continue with the CLI. Then complete the remaining steps in this procedure.
6. Type the following information as requested. Example values are shown here.
Note: Use your own values for each item.
Comma-separated list of DNS server(s): 10.64.0.13,10
NTP server name: time.ntpserver.com
Time zone: America/Los_Angeles
Subnet label for NIC eth0a: management
Subnet for NIC eth0a (use slash notation, for example, 10.11.0.0/16): 10.12.0.0/16
Comma-separated list of subnet types for the subnet on NIC eth0a [management,data]: management
MTU for the subnet on NIC eth0a [standard | jumbo | <integer>]: standard
Subnet label for NIC eth0b: management
Subnet label for NIC tg1a: Data1
Subnet for NIC tg1a (use slash notation, for example, 10.11.0.0/16): 172.0.1.0/22
Comma-separated list of subnet types for the subnet on NIC tg1a [management,data]: data
MTU for the subnet on NIC tg1a [standard|jumbo|<integer>]: standard
Subnet label for NIC tg1b: Data2
Subnet for NIC tg1b (use slash notation, for example, 10.11.0.0/16): 172.0.2.0/23
Comma-separated list of subnet types for the subnet on NIC tg1b [management,data]: data
MTU for the subnet on NIC tg1b [standard|jumbo|<integer>]: standard
Subnet label for NIC tg1c: Data1
Documentation Feedback: doc-feedback-hpe-storage@hpe.com