Replace a Controller

Before you begin
Use this procedure to replace a controller in your HPE storage array.
Time required:
Parts required:
Tools required:
Information required:
Support contact:
HPE recommends using the Maintenance Window functionality within the HPE InfoSight portal to inform HPE Support of
upcoming maintenance windows.
Refer to https://infosight.hpe.com/dashboards/nimble/wellness/maintenance-windows for more information.
You can disable automated support case generation during planned maintenance from the Manage Maintenance Windows
page. After a maintenance window is set, no further communication with HPE Support is required.
1
Controller A
Note:
If one controller fails, the other controller takes over. The array can function with one healthy controller while the
replacement is installed.
Replace the array controller if any of its components, such as the NVDIMM, have failed.
Replacement controllers are shipped without the PCIe cage installed. Before installing the replacement controller,
you must remove the PCIe cage from the failed controller and install it into the replacement controller.
45 minutes per controller
Replacement controller(s) ordered from HPE
ESD (electrostatic discharge) strap or appropriate grounding device
RMA (Return Materials Authorization) work order
Case number
Array name or serial number
The array serial number can be found on the back of Controller A.
See Support.
2
Controller B
Documentation Feedback: doc-feedback-hpe-storage@hpe.com
Maintenance Procedures 82