Maintenance Procedures
The following topics describe maintenance procedures for the HPE storage array.
Drive Maintenance
The procedures for maintaining drives are the same for the following:
Solid State Drives (SSDs)
Hard Disk Drives (HDDs)
Arrays
Expansion Shelves
How the Storage Array Handles a Failed Drive
The HPE storage array is designed to be highly available, with redundant components. With Triple+ Parity RAID, an Adaptive
Flash array continues serving data with up to two independent HDD failures. At the RAID level, three drives are dedicated to
parity, which is striped evenly across the RAID group. Data is reconstructed from parity onto the replacement disk when the
failed drive is replaced.
How to Tell that a Drive has Failed
Any of the following events can indicate that a hard disk drive (HDD) or solid state drive (SSD) has failed:
LEDs are solid red or off
Event appears in the Events list
Receipt of an alert email from the array.
1
Drive B (empty)
1 Drive fault
Replace a Failed Drive (SSD)
Use this procedure to replace SSDs in your HPE storage array or expansion shelf.
2
Drive A operation (populated)
Maintenance Procedures 73