Field Name
Options / Units
PTT Priority
W>R
R>W
R=W
RSSI Thresh. (dBm)
-50 to -127dBm
-100dBm
W.T.O.T. (sec)
0-2550 seconds, in
increments of 10
seconds
(0 = disabled,
displays as OFF)
R.T.O.T. (sec)
0-2550 seconds, in
increments of 10
seconds
(0 = disabled,
displays as OFF)
(0 = disabled,
displays as OFF)
R.D.O.D. (sec)
0-2550 seconds
0 seconds
2021-11-0
PDR8000® Portable Digital Repeater Programming Guide
Description
Specifies priority order of two types
of PTT requests:
• W = Wireline
• R = Rx of the Repeater
Received Signal Strength Indicator
Threshold specifies the signal level at
the input of the PDR8000 receiver,
required to validate the signal
Wireline Time Out Timer specifies
the maximum amount of time the
transmitter may be continuously
activated through the wireline signal.
Repeater Time Out Timer specifies
the maximum amount of time
repeater mode may be continuously
activated by subscriber through
receiver.
Repeater Drop Out Delay specifies
the amount of time repeater mode is
maintained following loss of received
signal.
8K088X04 R5.00
Notes
• W > R: Wireline has priority over
Repeater
• R > W: Repeater Rx has priority
over Wireline
• R = W: Repeater Rx and Wireline
have equal priority. Whichever
occurs first takes and maintains PTT
control.
Any value entered that is not an
increment of 10 is rounded up to the
next valid value.
Any value entered that is not an
increment of 10 is rounded up to the
next valid value.
This is also known as hang-time.
Page 52 of 98
Need help?