Field Name
Output Power Alarm
Antenna Switch
AFC Fast
Side LED
DFSI*
Fixed Station IP
Address
Fixed Station Port
Control Retry Timer
(ms)
Control Attempt
Limit
Connectivity Loss
Limit
2021-11-0
Options / Units
1-5dB
PDR8000 activates the output power
alarm if the difference in the
0 = OFF
measured RF Tx power and
programmed Tx power exceed this
threshold.
Disabled
Specifies whether the external
antenna switch is used for single
Enabled
antenna operation.
Enable/Disable
Enables or Disables the Fast AFC
Enable/Disable
Switches the LED above the PDR8000
'RF OUT' port on the side panel
ON/OFF.
0.0.0.0-
Standard IP address for the fixed
255.255.255.254
station. This value shall match what's
programmed in the DFSI host to
connect to this station.
0-65535
UDP Port at which the fixed station
supplies the Control Service
50006
200-2000
Retry period for control messages.
500
This period shall be used for all control
messages except for Heartbeat and
Acknowledgements.
1-10
Maximum number of attempts for
control messages
3
This number shall be used for all
control messages except for Heartbeat
and Acknowledgements
1-10
Maximum number of heartbeat losses
to allow
2
PDR8000® Portable Digital Repeater Programming Guide
Description
8K088X04 R5.00
Notes
Typically set to OFF
This field is only accessible when
Repeater Operation is set to Base
in the RF Configuration window.
Default setting is Enable. Set to
disable during calibration.
PDR8000 Suitcase only.
Page 48 of 98
Need help?