Polarity; Input Menu (Input); Input Type - Banner LTF12 Instruction Manual

Time of flight laser distance sensor with io-link
Hide thumbs Also See for LTF12:
Table of Contents

Advertisement

 
 Off One-Shot Timer (Off1Sho) 
 On Delay (OnDly) 
 On One-Shot Timer (On1Sho) 

Polarity

The Polarity option sets the discrete output polarity to either PNP (current sourcing) or NPN (current sinking). The physical
wiring of the sensor and the sensor polarity setting must match. 
Remote Input: Not available 
 Default: PNP 

Input Menu (INPUT)

Use this menu to view or change the:
Multi-function input type 
MENU INPUT
Select Menu Item
Press to Save Setting
Go Back to Parent Menu
Press and Hold to Go Back
to Run Mode
 Input Type 
The Type option sets the input type. 
Navigate: MENU › INPUT › Type 
Remote Input: Not available 
 Default: Disabled 
Input Type 
Teach 
LasrEnbl 
June 22, 2023
LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual
Off Delay 
OK 
OK 
N/A 
or
or
The remote input is used to TEACH and program the sensor. (Default) 
The remote input is used to control when the laser emitter is On/Off. 
Continued from page 26
Off One-Shot Timer 
OK 
N/A 
N/A 
Input Menu map
Type Teach
INPUT Type
Type LasrEnbl
Type SyncMstr
Type SyncSlve
Type Disabled
Default Setting
Description 
Continued on page 28
© Banner Engineering Corp.
On Delay 
On One-Shot Timer 
N/A 
N/A 
OK 
OK 
OK 
OK 
 
27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ltf24