6
Ensure that all raised floor tiles have been cut out accordingly to accommodate the power, SCSI, fibre,
and Ethernet cables to any of the frames.

Preparing for Module Attachment

Required tools: 2.5 mm hex wrench, 3 mm hex wrench
1
On the control module or far right expansion module, remove the storage magazines in sections 1- 5 of
column 4 of rack 1.
This will allow you to gain access to the 2.5 mm hex wrench screws that attach the right side panel to
the control module or last expansion module.
Top view of module
Rack 1 (back)
Rack 2 (front)
2
Remove the nine (9) 2.5 mm screws that attach the right side panel to the module.
Three screws are located at the front corner post, three at the back corner post,
Note
and three at the storage wall.