Installing The I/O Management Unit Cooling Assembly - ADIC Scalar i2000 Installation Manual

Table of Contents

Advertisement

The power supply in the top position is known as power supply 1 in the Library
Note
Management Console and the power supply in the bottom position is known as
power supply 2 in the Library Management Console.

Installing the I/O Management Unit Cooling Assembly

The I/O management unit cooling assembly contains the fans that regulate temperature for the I/O
management unit.
Required tools: #1 Phillips screwdriver
To install the I/O management unit cooling assembly
1
If it is not already open, open the back door of the library.
The power is on.
2
Slide the I/O management unit cooling assembly into the top slot of the I/O management unit chassis
until fully seated.
I/O management unit
3
If it is not already there, place the latch handle in the up position.
4
Using the #1 Phillips screwdriver or your fingers, tighten the thumbscrew on the I/O management unit
cooling assembly.
Scalar i2000 Installation Guide
49

Advertisement

Table of Contents
loading

Table of Contents