JUMPERS

MODULE STATUS
NTSC PAL
AUDIO GEN LCK
FRAME
STATUS
ON
OFF
J3
9.1.

TERMINATION JUMPERS

REF TERM
The REF TERM jumper J19 located on the rear of the card near the white multi-pin
connector, selects the reference video termination impedance. Either 75Ω or a high-
Z (27kΩ) termination impedance can be selected by placing the jumper in the "75"
(top justified) or "HI-Z" (bottom justified) positions, respectively.
9.2.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
FRAME STATUS
The FRAME STATUS jumper J3 located at the front of the module determines
whether local faults (as shown by the Local Fault indicator) will be connected to the
7700FR frame's global status bus.
To monitor faults on this module with the frame status indicators (on the PS FRAME
STATUS LED's and on the Frame's Fault Tally output) install this jumper in the ON
position. (Default) When this jumper is moved to the OFF position, local faults on
this module will not be monitored.
The Frame stat trigger menu item on the GPO configuration menu is used to
configure whether Fault condition 1 or Fault condition 2 will assert the frame status
fault line. Power supply faults will always assert the frame status fault line when J3
is installed in the ON position.
7735CEM-54
Gray background indicate un-implemented or un-tested features
EVERTZ (A) 7735CE
SFF POWER
GND
+12V

Figure 9-1 : Location of Jumpers on 7735CE Boards