The displayed settings are:
Object
• Port
• Flow Sampler Enabled
• Flow Sampler
Sampling Rate
• Flow Sampler Max.
Header
• Counter Poller
Enabled
• Counter Poller Interval
User's Manual of GS-6320 and MGS-6320 Managed Switches
Description
The port number for which the configuration below applies.
Enables/disables flow sampling on this port.
The statistical sampling rate for packet sampling. Set to N to sample on average
1/Nth of the packets transmitted/received on the port.
Not all sampling rates are achievable. If an unsupported sampling rate is
requested, the switch will automatically adjust it to the closest achievable. This
will be reported back in this field. Valid range is 1 to 32767.
The maximum number of bytes that should be copied from a sampled packet to
the sFlow datagram. Valid range is 14 to 200 bytes with default being 128 bytes.
To have room for any frame, the
bytes larger than the maximum header size. If the
not take into account the maximum header size, samples may be dropped.
Enables/disables counter polling on this port.
With counter polling enabled, this specifies the interval - in seconds - between
counter poller samples. Valid range is 1 to 3600 seconds.
246
maximum datagram size
should be roughly 100
maximum datagram size
does