Table 12 Error Blink Codes - TransAct Ithaca 280 Programmer's Manual

Thermal receipt printer
Table of Contents

Advertisement

How to Operate the ITherm
Fully-recoverable and Status
A fully-recoverable error will restart printing exactly where it stopped when the error
occurred. Printing will resume after error has been properly addressed. A status
recoverable error is very similar to a fully-recoverable error. Additionally, status is used
to display when the printer consumables may need replacing.
Semi-recoverable
A semi-recoverable error is determined by whether or not the printer has to be shut off
and turned back on while attending to the problem. The amount of information lost is
dependent on the type of error and the state of the information being processed.
Non-recoverable
A non-recoverable error produces information loss.
Error Blink Codes
If during normal operation, the
a minor error occurred. The
Cycling the power restarts the printer. Blink patterns are defined as follows.
1 Blink
__█__________________█______
2 Blink
__█__█_______________█__█___
3 Blink
__█__█__█____________█__█__█_
A similar pattern is followed for other blink counts. Error indications are as follows:
Error Indicated
Unused
Configuration Read
Configuration Write
Software Error
Auto Cutter Error
Unused
User Store Format Error
Electronic Journal Format Error
Flash Operation Error
Internal Memory Error
Communication Adapter Error
Operating System Error

Table 12 Error Blink Codes

28-04430
®
280
indicator is lit and the
ERROR
indicator shows the error by blinking a pattern.
POWER
(1 blink, pause)
(2 blinks, pause)
(3 blinks pause)
Rev K
®
iTherm
280 Programmer's Guide
indicator is blinking,
POWER
Blink Count
1
2
3
4
5
6
7
8
9
12
14
15
Page 43