Programming Codes
[ENQ] <23>
Inquire user-store status
ASCII
[ENQ] <23>
Hexadecimal 05H 17H
Decimal
<5> <23>
Function
The [ENQ] <23> command reports on the user-store status.
Response
[ACK] <23> <Report> <0>
Where <23> is the echo of command ID. The report is a null terminated string with the
following format:
12345[CR][LF] (Free user store)
12345 Type Name...[CR][LF] (First entry) etc.
12345 Type Name...[CR][LF] (Last entry) <0>
Type
The type field describes the type of information.
M = macro
C = character definition
[ENQ] <24>
Inquire Color status
ASCII
[ENQ] <24>
Hexadecimal 05H 18H
Decimal
<5> <24>
Function
The [ENQ] <24> command reports Color Cartridge status.
Response
[ACK] <24> <Length+40><n
Where <24> Is the echo of command
<n
>
Secondary Pen Color 0 = Not installed, 1 = Red, 2 = Green, 4 = Blue
1
<n
>
Primary Pen Color 1 = Red, 2 = Green, 4 = Blue 16 = Black
2
<n
>
Pen Status
3
bit 0 = Not defined
bit 1 = Not defined
bit 2 = Secondary Cartridge not installed
bit 3 = Primary Cartridge not installed
bit 4 = Secondary Cartridge low on ink.
bit 5 = Primary Cartridge low on ink.
bit 6 = 1 always
bit 7 = 0 always
[ESC] [EM]P<n>
ASCII
[ESC] [EM] P<n>
Hexadecimal 1BH 19H 50H <n>
Decimal
<27> <25> <80><n>
IPCL
None
EPOS
None
Description This command activates the periodic status back feature.
automatically return an [ENQ]<20> status (See page Error! Bookmark
28-04430
iTherm
><n
><n
>
1
2
3
Activate Periodic Status Back