Performing A Self-Test; Checking For Option 003 Or Option - HP 3324A Operating And Programming Manual

Synthesized function/sweep generator
Hide thumbs Also See for 3324A:
Table of Contents

Advertisement

Performing a
Self-test
Note
Checking for
Option 003 or
Option 004
Two levels of self-test are available, a standard one and
one in which everything is tested. The standard test is a
simple pass or fail test, whereas the "all" test is one in
which the reason for a failure is given. The "all" test is
also an interactive test. If an error is shown return the
instrument to an HP Service Center for repair.
To perform one of the self-tests, display "selft: std./all"
in the display. Place the cursor on the self-test that you
wish to perform and press (Select).
The "all" self-test performs a reset (as at power-on) and
cannot be selected via HP-IB.
If you have the phase calibration options 003 or
installed in some instruments you can check to see what
is in which installed by scrolling in the UTILS menu,
until either "phase cal SLAVE" or "phase cal MASTER"
is shown. "phase cal SLAVE" means that option 003 is
installed and "phase cal MASTER" means that option
004 is installed. If neither options are installed, neither
of these two statements are shown. See Automatic Phase
Calibration in Chapter 5 for a description of how the
calibration works.
004
Utilities 8-5