Safety Inspection Checklist - Lenovo ThinkEdge SE350 V2 Hardware Maintenance Manual

Hide thumbs Also See for ThinkEdge SE350 V2:
Table of Contents

Advertisement

• To view the error LEDs on the system board and internal components, leave the power on.
• You do not have to turn off the server to remove or install hot-plug USB devices. However, you must turn
off the server and disconnect the power source from the server before performing any steps that involve
removing or installing internal cables.
• Blue on a component indicates touch points, where you can grip to remove a component from or install it
in the server, open or close a latch, and so on.
• Terra-cotta on a component or a terra-cotta on or near a component indicates that the component can be
hot-swapped if the server and operating system support hot-swap capability, which means that this
component can be removed or installed while the server is still running. (Terra-cotta can also indicate
touch points on hot-swap components.) See the instructions for removing or installing a specific hot-swap
component for any additional procedures that you might have to perform before removing or installing the
component.
• The Red strip on the drives, adjacent to the release latch, indicates that the drive can be hot-swapped if
the server and operating system support hot-swap capability. This means that the drive can be removed
or installed while the server is still running.
Note: See the system specific instructions for removing or installing a hot-swap drive for any additional
procedures that you might need to perform before removing or installing the drive.
• After finishing working on the server, make sure to reinstall all safety shields, guards, labels, and ground
wires.

Safety inspection checklist

Use the information in this section to identify potentially unsafe conditions with your server. As each machine
was designed and built, required safety items were installed to protect users and service technicians from
injury.
Note: This device is not intended for use in the direct field of view at visual display workplaces. To avoid
incommoding reflections at visual display workplaces, this device must not be placed in the direct field of
view.
CAUTION:
This equipment must be installed or serviced by trained personnel, as defined by the NEC, IEC 62368-
1 & IEC 60950-1, the standard for Safety of Electronic Equipment within the Field of Audio/Video,
Information Technology and Communication Technology. Lenovo assumes you are qualified in the
servicing of equipment and trained in recognizing hazards energy levels in products. Access to the
equipment is by the use of a tool, lock and key, or other means of security, and is controlled by the
authority responsible for the location.
Important: Electrical grounding of the server is required for operator safety and correct system function.
Proper grounding of the electrical outlet can be verified by a certified electrician.
Use the following checklist to verify that there are no potentially unsafe conditions:
1. Make sure that the power is off and the power cord is disconnected.
2. Check the power cord.
• Make sure that the third-wire ground connector is in good condition. Use a meter to measure third-
wire ground continuity for 0.1 ohm or less between the external ground pin and the frame ground.
• Make sure that the power cord is the correct type.
To view the power cords that are available for the server:
a. Go to:
http://dcsc.lenovo.com/#/
ThinkEdge SE350 V2 Hardware Maintenance Guide
2