Electrical Data, 525-690 V Ac - Danfoss VLT AQUA Drive FC 202 Operating Manual

355-800 kw, enclosure sizes e1h-e4h
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Operating Guide | VLT® AQUA Drive FC 202
FC 202
2
- Brake or regen [mm
(AWG)]
Maximum number and size of cables per phase (E4h)
2
- Mains and motor [mm
(AWG)]
2
- Brake [mm
(AWG)]
- Load share or regen [mm
Maximum external mains fuses [A]
Estimated power loss at 400 V [W]
Estimated power loss at 460 V [W]
Efficiency
(3)
Output frequency [Hz]
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Power card overtemperature trip [°C (°F)]
Fan power card overtemperature trip [°C (°F)]
Active in-rush card overtemperature trip [°C (°F)]
1
9.7 Fuses
For fuse ratings, see
.
2
Typical power loss is at normal conditions and expected to be within ±15% (tolerance relates to variety in voltage and cable conditions.) These values are based on a typical motor
efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for dimensioning of drive cooling. If the switching frequency is higher than the default
setting, the power losses can increase. LCP and typical control card power consumptions are included. For power loss data according to EN 50598-2, refer to www.danfoss.com/
vltenergyefficiency. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for slots A and B each add only 4 W.
3
Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy efficiency class, see
Conditions
. For part load losses, see www.danfoss.com/vltenergyefficiency.
9.1.2 Electrical Data, 525–690 V AC
Table 47: Electrical Data, Mains Supply 3x525–690 V AC
FC 202
High/normal overload
High overload=150% or 160% torque for a duration of 60 s.
Normal overload=110% torque for a duration of 60 s.
Typical shaft output at 525 V [kW]
Typical shaft output at 575 V [hp]
Typical shaft output at 690 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 525 V) [A]
Intermittent (60 s overload) (at 525 V) [A]
132 | Danfoss A/S © 2020.01
2
(AWG)]
(1)
(2) (3)
(2) (3)
N500
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
8352
7182
0–590
110 (230)
80 (176)
85 (185)
85 (185)
85 (185)
N450
N500
HO
NO
HO
315
355
355
400
450
400
355
450
400
E1h/E3h
E1h/E3h
395
470
429
593
517
644
Specifications
N560
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
1200
1200
9473
9449
11102
7809
7771
0.98
0.98
0–590
100 (212)
80 (176)
85 (185)
85 (185)
85 (185)
9.4 Ambient
N560
NO
HO
400
400
500
500
500
500
E1h/E3h
523
523
575
785
AQ275652274277en-000101 / 130R0708
9236
NO
450
600
560
596
656

Advertisement

Table of Contents
loading

Table of Contents