Danfoss VLT AQUA Drive FC 202 Operating Manual page 82

355-800 kw, enclosure sizes e1h-e4h
Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Operating Guide | VLT® AQUA Drive FC 202
Table 24: Analog Voltage Feedback Transducer (4-wire)
Drive
12
+24 V
+24 V
13
18
D IN
D IN
19
COM
20
D IN
27
D IN
29
D IN
32
D IN
33
D IN
37
+10 V
50
+
A IN
53
A IN
54
COM
55
A OUT
42
-
COM
39
0-10 V
U - I
A54
80 | Danfoss A/S © 2020.01
Parameters
Function
Parameter 6-20 Terminal 54 Low Voltage
Parameter 6-21 Terminal 54 High Voltage
Parameter 6-24 Terminal 54 Low Ref./Feedb. value
Parameter 6-25 Terminal 54 High Ref./Feedb. Value
*=Default value
Notes/comments:
D IN 37 is an option.
Wiring Configuration Examples
Setting
0.07 V*
10 V*
0*
50*
AQ275652274277en-000101 / 130R0708