Points of maintenance

Hydraulic oil tank (1)

- Check oil level on sight glass (A).
The oil level must be up to the centre of
A
the sight glass when the cylinders are re-
tracted.
If all the cylinders are extended, the level
A
can fall below the sight glass.
The sight glass is located on the side of
A
the tank.
For filling in the oil:
- Remove cap (B).
- Fill in oil through the filling opening un-
til the oil level rises to the centre of the
sight glass (A) (+/- 5mm).
- Screw cap (B) on again.
Regularly remove dust and dirt from the
A
oil tank vent (C). Clean the surfaces of
the oil cooler.
Use only the recommended hydraulic
m
oils - see section "Recommended hy-
draulic oils".
When filling for the first time, all hydraulic
A
cylinders should be extended/retracted
at least 2x for ventilation!
B
A
C
F 60 5