Two high-pressure cartridges (6) are lo-
A
cated on both of the travel drive pumps (5).
The following activities must be carried
out to activate the towing function:
- Loosen lock nut (7) half a turn.
- Screw in the bolt (8) until increased re-
sistance occurs. Then screw the bolt a
further half turn into the high-pressure
cartridge.
- Tighten the lock nut (7) to a torque
of 22 Nm.
On completion of the towing process, re-
m
store the initial status.
- Attach the tow bar to the coupling (9)
located in the bumper.
Now carefully and slowly tow the paver
A
finisher out of the construction area.
Only ever tow the shortest distance to
m
the means of transport or the next park-
ing possibility.
The max. permissible towing speed
m
is 10 m/min!
In hazardous situations, a towing speed
of 15 m/min is only permitted temporarily.
The max. permissible towing eye (9)
m
load is: 200 kN