Cannot ping the Flex System Manager management node on the management
network
Use the information in this section to troubleshoot the compute node when one or more compute nodes
cannot ping the management node on the management network.
Single node cannot ping the management node in the same chassis
Use the information in this section to troubleshoot a single compute node that cannot ping the Flex System
Manager management node in the same chassis on the management network.
Action
Complete the following steps until the problem is solved:
1. Make sure that the management node is powered on and is not hung, by logging in to the management
node. If you are unable to log in from the management network, attempt to log in from the data network.
If the management node is powered on and hung, perform a virtual reseat of the management node from
the CMM.
2. Make sure that the CMM is powered on and is not hung, by pinging the CMM from the management
node. If the CMM is powered on and hung, reset the CMM. Make sure that the IMM, the management
node, and CMM are all on the same subnet.
3. Make sure that the compute node is the only one in the chassis that the management node cannot ping.
If it is not, follow the steps in
on page
863. Make sure that the compute node appears on the chassis map (it might not be fully
discovered by the management node software).
4. Make sure that the system-management processor in each compute node has a valid IP address by
checking the chassis map of the remote chassis.
Note: If the CMM recently lost connection to the DCHP server, you must reset the IMM by using the
CMM interface so that a new IP address can be acquired.
5. In the CMM user interface, click Chassis Management > Component IP Configuration and make sure
that the IP address that is listed is the same as the IP address that is displayed in the Setup utility. If it is
not the same, configure the IMM network settings correctly.
6. Check
http://www.lenovo.com/support
view the release notes for a firmware update to determine the issues that are addressed by the update.
7. Check
http://www.lenovo.com/support
8. Remove the compute node and make sure that the connectors on the chassis midplane and the node
are not damaged.
9. (Trained service technician only) Complete the following steps:
a. Force the link/duplex speed.
b. Check the connectors on the node and the chassis midplane to make sure that no pins are bent.
c. Replace the compute node.
Single node cannot ping the management node in a different chassis
Use the information in this section to troubleshoot a single compute node that cannot ping the Flex System
Manager management node in a different chassis on the management network.
Action
Complete the following steps until the problem is solved:
1. Make sure that the management node is powered on and is not hung, by logging in to the management
node. If you are unable to log in from the management network, attempt to log in from the data network.
If the management node is powered on and hung, perform a virtual reseat of the management node from
the CMM.
Lenovo Flex System x440 Compute NodeInstallation and Service Guide
862
"Multiple nodes cannot ping the management node in the same chassis"
for any firmware updates that might apply to this issue. You can
for any service bulletins that are related to network connectivity.