Critical - Temperature
SNMP Trap ID
0
CIM Information
Prefix: PLAT ID: 0530
User Response
Complete the following steps until the problem is solved:
1. Check the Chassis Management Module or Flex System Manager event log for any fan- or
cooling-related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If there are no other thermal issues, replace the I/O expansion adapter.
• 8007060f-2201ffff : Sensor BOFM Config Err has transitioned to non-recoverable.
UEFI cannot read the fabric manager configuration from the IMM.
May also be shown as 8007060f2201ffff or 0x8007060f2201ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0530
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Information Center for the appropriate user response.
Related links
Finding the UEFI diagnostic code
• 80070614-2201ffff : Sensor TPM Phy Pres Set has transitioned to non-recoverable.
Trusted Platform Module (TPM) initialization error.
May also be shown as 800706142201ffff or 0x800706142201ffff
Severity
Error
Serviceable
Yes
Automatically notify support