Table 7. System board diagnostic LED information (continued)
LED
Color
DPL03
Yellow
DVL02
Yellow
DML01 DML48
Yellow
DLLACT10
Green
DLLACT11
Green
DLLACT20
Green
DLLACT21
Green
DLLUP10
Green
DLLUP11
Green
DLLUP20
Green
DLLUP21
Green
DLPWROK1
Green
DLPWROK2
Green
DPWRFAULT
Yellow
DS862
Green
DS913
Green
DSL01
Yellow
DSL02
Yellow
DSAS_LF10
Yellow
Yellow
DSAS_LF11
DSAS_LF20
Yellow
Lenovo Flex System x440 Compute NodeInstallation and Service Guide
64
LED name
CPU 4 error
DC fault
DIMM x error
Ethernet 1-0 activity
Ethernet 1-1 activity
Ethernet 2-0 activity
Ethernet 2-1 activity
Ethernet 1-0 link
Ethernet 1-1 link
Ethernet 2-0 link
Ethernet 2-1 link
Ethernet 1 power OK
Ethernet 2 power OK
Power fault
RTMM heartbeat
IMM heartbeat
SAS back plane 1 error
SAS Back Plane 2 error
SAS 1-0 link failure
SAS 1-1 link failure
SAS 2-0 link failure
Description
The IMM2 lights this LED and the fault LED when
microprocessor 4 is defective.
The IMM2 lights this LED and the fault LED when
there is a power fault on one of the power rails.
The IMM2 lights any of these LEDs and the fault LED
when any DIMMs 1 – 48 are defective.
This LED lights when there is Ethernet activity on port
0 of LOM controller 1.
This LED lights when there is Ethernet activity on port
1 of LOM controller 1.
This LED lights when there is Ethernet activity on port
0 of LOM controller 2.
This LED lights when there is Ethernet activity on port
1 of LOM controller 2.
This LED lights when port 0 on LOM controller 1 is
connected to the network.
This LED lights when port 1 on LOM controller 1 is
connected to the network.
This LED lights when port 0 on LOM controller 2 is
connected to the network.
This LED lights when port 1 on LOM controller 2 is
connected to the network.
This LED lights when power to LOM controller 1 is on
and working properly.
This LED lights when power to LOM controller 2 is on
and working properly.
This LED lights when there is an overcurrent fault on
one of the 12 V power rails.
This LED lights when there is activity on the RTMM.
This LED lights when there is activity on the IMM2.
The IMM lights this LED and the fault LED when there
is a problem with SAS backplane 1.
The IMM2 light this LED and the fault LED when there
is a problem with SAS backplane 2.
The IMM lights this LED and the fault LED when there
is a fault with the link between the SAS controller and
SAS Port 0 on SAS backplane 1.
The IMM lights this LED and the fault LED when there
is a fault with the link between the SAS controller and
SAS Port 1 on SAS backplane 1.
The IMM2 lights this LED when there is a fault with the
link between the SAS controller and SAS port 0 on
SAS backplane 2.

Advertisement