Lenovo Flex System x440 Compute Node Installation And Service Manual page 628

Table of Contents

Advertisement

Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Power On
SNMP Trap ID
24
CIM Information
Prefix: PLAT ID: 0107
User Response
Information only; no action is required.
• 816f000d-0400ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
Presence of drive 0 is no longer detected. If hard drive is absent from drive bay a filler is required.
May also be shown as 816f000d0400ffff or 0x816f000d0400ffff
Severity
Info
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0163
User Response
– If drive was intentionally removed, no action required.
– Make sure that the drive properly seated.
– If drive is properly seated, replace the drive.
• 816f000d-0401ffff : The Drive [StorageVolumeElementName] has been removed from unit
[PhysicalPackageElementName].
Presence of drive 1 is no longer detected. If hard drive is absent from drive bay a filler is required.
May also be shown as 816f000d0401ffff or 0x816f000d0401ffff
Severity
Info
Serviceable
Yes