4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the
DIMM.
• 806f0a07-0301ffff : CPU 1 is operating in a Degraded State.
The processor is being throttled due to thermal or power conditions.
May also be shown as 806f0a070301ffff or 0x806f0a070301ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0038
User Response
Complete the following steps:
1. Check the CMM or FSM event log for any fan- or cooling-related issues or power-related issues..
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
• 806f0a07-0302ffff : CPU 2 is operating in a Degraded State.
The processor is being throttled due to thermal or power conditions.
May also be shown as 806f0a070302ffff or 0x806f0a070302ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - CPU
SNMP Trap ID
42
CIM Information
Prefix: PLAT ID: 0038
User Response
Lenovo Flex System x440 Compute NodeInstallation and Service Guide
552