Lenovo Flex System x440 Compute Node Installation And Service Manual page 394

Table of Contents

Advertisement

Automatically notify support
No
Alert Category
System - Boot failure
SNMP Trap ID
25
CIM Information
Prefix: PLAT ID: 0186
User Response
This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of
the Info Center for the appropriate user response.
Related links
Finding the UEFI diagnostic code
• 806f011b-0c01ffff : The connector LightPath has encountered a configuration error.
The light path LED card is not detected.
May also be shown as 806f011b0c01ffff or 0x806f011b0c01ffff
Severity
Error
Serviceable
Yes
Automatically notify support
Yes
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0266
User Response
Complete the following steps until the problem is solved:
1. Make sure that the cable from the light path LED card to the system board is securely connected.
2. Replace the light path diagnostics panel.
• 806f011b-1f03ffff : The connector [PhysicalConnectorElementName] has encountered a
configuration error.
The SAS cable connections between the SAS backplane 1 and the system board are not complete.
May also be shown as 806f011b1f03ffff or 0x806f011b1f03ffff
Severity
Error
Serviceable
Yes
Automatically notify support