A drive failed causing RAID redundancy to be degraded.
May also be shown as 8007010d0b01ffff or 0x8007010d0b01ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
Check the physical drive and replace the bad one.
• 8007010f-2201ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
The GPT (GUID Partition Table) in the disk LUN (Logical Unit Number) is corrupt and may make the data in
the LUN inaccessible to the system and prevent boot.
May also be shown as 8007010f2201ffff or 0x8007010f2201ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
Warning - Other
SNMP Trap ID
60
CIM Information
Prefix: PLAT ID: 0520
User Response
Complete the following steps:
1. Check the IBM support site for service bulletins or firmware updates that apply to this GPT error.
2. Set the UEFI setting "DISK GPT Recovery" to "Automatic".
3. Replace the corrupt disk.
GPT Status : Sec Rollback Err : Secure Boot Err :
• 8007010f-2582ffff : Sensor [SensorElementName] has transitioned from normal to non-critical
state.
Less than optimal I/O resource configuration.