Lenovo Flex System x440 Compute Node Installation And Service Manual page 115

Table of Contents

Advertisement

Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Lenovo Support website
Latest level of DSA
• 201-845-003 : Standalone Memory Test Aborted
Chipset Error: Problem clearing MSR machine check control registers.
Recoverable
No
Severity
Warning
Serviceable
No
Automatically notify support
No
User Response
Complete the following steps:
1. Perform the actions mentioned one at a time and try the test after each action.
2. If the problem remains, contact your technical-service representative.
3. Turn off the system and disconnect it from power. Wait for 45 seconds. Reseat DIMM(s).
Reconnect it to power.
4. Make sure that DSA and BIOS/uEFI are at the latest level.
Related links
Lenovo Support website
Latest level of DSA
• 201-859-000 : Standalone Memory Test Aborted
INVALID XSECSRAT type.
Recoverable
No
Severity
Warning
Serviceable
.
Chapter 6
Troubleshooting
105