Lenovo Flex System x440 Compute Node Installation And Service Manual page 544

Table of Contents

Advertisement

User Response
Complete the following steps:
1. Check the CMM or FSM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the
DIMM.
• 806f090c-2014ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled.
Memory has been Throttled.
May also be shown as 806f090c2014ffff or 0x806f090c2014ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix: PLAT ID: 0142
User Response
Complete the following steps:
1. Check the CMM or FSM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the chassis is not obstructed and that fillers are
in place and correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. Make sure that the DIMM baffles are in place.
5. If the problem persists and there are no other DIMMs with the same indication, replace the
DIMM.
• 806f090c-2015ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled.
Memory has been Throttled.
May also be shown as 806f090c2015ffff or 0x806f090c2015ffff
Severity
Warning
Lenovo Flex System x440 Compute NodeInstallation and Service Guide
534